![SENSTAR Symphony 7.2 Series User Manual Download Page 52](http://html.mh-extra.com/html/senstar/symphony-7-2-series/symphony-7-2-series_user-manual_1244253052.webp)
Symphony Server
Alarm monitor information
Object
Description
alarmNotif
This object is the notification sent when an alarm occurs.
Trap
alarmNotifyCameraId
This object is the identifier of the camera that recorded the alarm.
alarmNotifyCameraName
This object is the name of the camera that recorded the alarm.
alarmNotifyUserId
This object is the identifier of the user who marked the alarm.
alarmNotifyUserName
This object is the name of the user who marked the alarm.
alarmNotifyMarkedDelay
This object is the time at which the alarm was marked.
alarmNotifyFalseAlarm
This object is whether the alarm is a false alarm.
alarmNotifyRuleId
This object is the identifier of the rule causing the alarm.
alarmNotifyRuleName
This object is the name of the rule causing the alarm.
alarmNotifyDBId
This object is the identifier of the alarm.
alarmNotifyComment
This object is the comment associated with that alarm.
alarmNotifyMSSinceChange
This object is the milliseconds between when the alarm occurred
and when it was detected.
Device Movement monitor information
Object
Description
devicesMovedNotif
This object is the notification sent when a device moves from one
server to another server.
Trap
sourceServerId
This object is the identifier of the server from which the device
moved.
destinationServerId
This object is the identifier of the server to which the device
moved.
numberDevicesMoved
This object is the number of devices that moved from the source
server to the destination server.
Senstar Symphony User Guide