Symphony Server
General
The General Settings tab in the server configuration interface is the interface for configuring settings
that apply to all of the Symphony Server instances in the server farm.
Configure video storage for a server farm
You can set a global video storage setting for a Symphony Server farm.
The global setting takes effect when you do not configure video storage settings for individual
Symphony Server instances.
1.
In the server configuration interface, click
Settings
>
General Settings
.
2.
In the
Video Storage
section, select
Limit the number of days video is stored
.
3.
Set the maximum number of days to save video.
4.
To keep video metadata after the video is deleted, select
Keep metadata longer
.
5.
Set the maximum number of days to save video metadata.
6.
Click
Save
.
Configure SNMP
You can configure Symphony to send SNMP data to a SNMP client.
1.
In the server configuration interface, click
Settings
>
General Settings
.
2.
Select
Enable SNMP
.
3.
In the
Data polling rate
, set how often (in seconds) SNMP sub-agents poll for data.
4.
In the
Footage size polling
set how often (in seconds) Symphony updates the size of the
footage.
5.
Click
Save
.
6.
Restart the Symphony services.
7.
Configure the Windows SNMP Agent Service on the computer that hosts the Symphony Server.
SNMP object identifiers
Server information
Object
Description
serverId
This object is the unique identifier of the Symphony Server.
serverName
This object is the name of the Symphony Server.
Version information
Object
Description
serverVersion
This object is the assembly version of the Symphony Server
software.
webserviceVersion
This object is the version of the Symphony Web service protocol.
cameraMessageVersion
This object is the version of the Symphony camera message
protocol.
Senstar Symphony User Guide