![SENSTAR Symphony 7.2 Series User Manual Download Page 115](http://html.mh-extra.com/html/senstar/symphony-7-2-series/symphony-7-2-series_user-manual_1244253115.webp)
Symphony Client
Create a heat map image report
The heat map image report displays a graphical representation of traffic patterns for a specific time.
1.
In the client interface, click
Reports
.
The Report Designer opens in a browser.
2.
Log in to the Report Designer.
3.
Click
New Report
.
4.
Type a name for the report.
5.
In the
Report Type
list, select
Heat Map Image
.
6.
To allow other users to run the report, select
Allow other users to run this report
.
7.
Click
OK
.
8.
In the
Cameras
section, perform the following tasks to add the cameras that provide
information for the report:
a) Click
Add Cameras
.
b) Select one or more cameras.
You can search for cameras by camera name.
c) Click
OK
.
9.
In the
Zone Selection
section, perform the following tasks to determine which zones in the
camera view generate data for the report:
a) Click
Add Zone
.
b) Move or reshape the zone.
c) To rename the zone, click
Rename Zone
, type a new name, and click
OK
.
d) Repeat to add another zone.
10. In the
Sensitivity
section, perform the following tasks to set how sensitive the heat map is to
events:
a) To set the number of intersections that must occur before the heat map starts registering
intersections for a zone, select
Minimum intersections
and type the value.
b) To set the number of intersections that must occur before the heat map stops updating the
value for a zone, select
Maximum Intersections
and type a value.
c) To set how long an object must remain stationary before the heat map starts registering
dwelling objects for a zone, select
Minimum Dwell Time
and set the time.
d) To set how long an object remains stationary before the heat map stops updating the
value for a zone, select
Maximum Dwell Time
and set the time.
e) To set how long an object must be stationary before it is considered as dwelling, select
Dwell Threshold
, and set the time.
11. In the
Date Range
section, perform the following tasks to determine the data that the report
includes:
a) In the
Start including data from
section, define the start of the data.
b) In the
Stop including data after
section, define the end of the data.
c) To use data from a specific time range from each day, select
Use custom time range for
data collection
and specify the time range.
12. In the
Schedule
section, perform the following tasks to run the report automatically:
a) Select
Schedule Enabled
.
b) In the
Recurrence
section, set when the report runs.
c) In the
Schedule start
section, set when the report starts running automatically.
d) In the
Schedule finish
section, set when the report stops running automatically.
Senstar Symphony User Guide
115