![SENSTAR Symphony 7.2 Series User Manual Download Page 53](http://html.mh-extra.com/html/senstar/symphony-7-2-series/symphony-7-2-series_user-manual_1244253053.webp)
Symphony Server
Health monitor information
Object
Description
healthMonitorFaultNotification
This object is the notification sent when the health monitor
detects a fault.
Trap
healthMonitorActionNotification
This object is the notification sent when the health monitor takes
an action in response to a fault.
Trap
healthMonitorName
This object is the name of the associated health monitor.
healthMonitorAction
This object is the action that the health monitor took in response
to a fault.
Configure mobile connections
You can configure Symphony to support connections with Symphony mobile applications on mobile
devices.
The mobile connections functionality in Symphony replaces the Mobile Bridge standalone
application. For more information on the Mobile Bridge standalone application, see the
Symphony
Mobile Bridge Installation Guide
.
1.
In the server configuration interface, click
Settings
>
General Settings
.
2.
Navigate to the
Mobile Connections
section.
3.
To select the SSL certificate, click
Change
, select the certificate, and click
OK
.
4.
In the
Mobile Port
field, set the port that Symphony uses to listen for requests from mobile
devices.
5.
In the
Video Proxy Port
field, set the port that Symphony uses to stream video to and receive
video from mobile devices.
6.
To allow Symphony to send push notifications to iOS devices, select
Enable iOS Notifications
.
7.
Click
Save
.
General settings
Video
Setting
Description
Time based video playback
restriction applied at
This setting determines how long (in minutes) after video is
recorded that a user can view the video in the Symphony Client.
Video storage
Setting
Description
Limit the number of days video
is stored
This setting determines whether Symphony deletes video older
than the set number of days.
Senstar Symphony User Guide
53