Buried cable installation
FiberPatrol FP1150 Product Guide
Page 59
•
smallest allowable bend radius, armored sensor cable: during installation (dynamic) 30 cm
(12 in.); installed (static) 15 cm (6 in.) (see
Figure 68:
)
•
sensor cable tensile rating during installation: 2700 N (600 lbf)
•
sensor cable splices: FiberPatrol sensor cable fibers require high quality fusion splices
•
the fusion splices are contained inside splice trays
Note
Vegetation within the 12 m (40 ft.) clearance area should be kept below a
height of 30 cm (12 in.).
Figure 67: Minimum separation distances from obstacles
Figure 68: Smallest allowable bend radius (sensor cable)
6 m (20 ft.)
6 m (20 ft.)
sensor cable
min. clear area
min. clear area
NOTE:
ground surface
2 m (6.6 ft.) typical
The clear area must be kept free of running water.
30 cm
static bend radius
(12 in.)
15 cm
(after installation)
dynamic bend radius
(during installation)