Fences
FiberPatrol FP1150 Product Guide
Page 35
Solid wall conduit
•
Both ends of the conduit must be sealed to prevent water from entering the conduit and
freezing.
•
Flexible conduit can be bent and formed into the required shape for a cable bypass.
•
The minimum bend radius for flexible solid wall conduit is 46 cm (18 in.). (If the conduit is
kinked during bending it must be replaced.)
•
If conduit sections are used, the sections must be glued together (water tight).
•
Use conduit sweeps. Do not use 90º elbows. (Cable bend radius rules must be followed.)
•
Bury the conduit at least 30 cm (1 ft.) below ground.
Figure 39 Split wall conduit
Figure 40 Conduit fittings
Figure 41 Solid wall conduit
split wall conduit
split wall conduit couplers
split wall conduit sweeps (not elbows)
water tight rain plugs are required for sites
use cement at joints
which experience periods of freezing temperatures
for solid wall conduit
flexible solid wall conduit is required for areas with freezing temperatures