Page 128
FiberPatrol FP1150 Product Guide
System menu
System > Login - Displays the Login Dialog that is used for changing the Access Level while the
FiberPatrol software is running. If an incorrect password is entered or the Cancel button is
selected, the software continues to run with the same Access Level.
System > Export Log Files - Saves the contents of the system logs into Log Files and clears the
system logs.
System > Export Images - Saves an image (jpg) of the current window.
System > Export All Images - Saves images (jpg) from the current window.
System > Print Window - Prints an image of the current window via the Windows default printer.
System > Exit - Shuts down the FiberPatrol software (displays login dialog for password entry).
Manage menu
The Manage menu provides access to the Clear All Alarms, Zone Masking, Zone Definition,
Change Password and Test Alarm functions.
Manage > Clear All Alarms - Clears all current alarms without displaying the Alarm Dialog. This
function is available on the Alarms sub-panel as the Clear All button.
Manage > Zone Masking - see
Zone Masking (Access) on page 131
Manage > Zone Definition - see
Manage > Change Password - see
Password maintenance on page 132
Manage > Test Alarm - The Test Alarm function is used to simulate an alarm. This function
generates a simulated alarm at a random location, and is generally used for demonstration,
personnel training and functionality verification.
Configure menu
Configure > Save Configuration - Saves the current system settings into the configuration file.
Configure > Load Configuration - Loads settings from the configuration files. Used for updating the
FiberPatrol IDS after the configuration files have been externally modified or replaced.
Configure > Alarm Auto clearing - see
Alarm Auto Clearing on page 132
.
Configure > Remote Interface - see
.
Configure > Hardware Interfaces - Hardware Interfaces is a legacy holdover from previous
versions of FiberPatrol, and does not apply to the current system.
Configure > Reset Controller - Resets the connection to the light signal hardware.
Configure > Factory Configuration > Revert - Resets the system configuration to the original
system settings when used at the Supervisor access level.
Configure > Factory Configuration > Update - Updates the Factory settings to the current system
settings when used at the Installer access level.
Note
System settings that are available to the Supervisor access level are
automatically saved to the configuration file.