FiberPatrol components
FiberPatrol FP1150 Product Guide
Page 13
Fiber connection module
The fiber connection module is contained in a 1 RU fiber patch panel next to the sensor unit in the
equipment rack. It includes a splice tray to hold the fusion splices between the sensor unit and the
two sensor fibers in the lead cable, as well as 2 terminated patch cords that connect to the SU.
The splice tray includes six unused protective sleeves, which are available to provide access to
the dark fibers in the sensor cable. Optionally, a second splice tray can be added for making
connections to any additional fibers that are being used at the site. A dual end module is included
in the fiber patch panel. Refer to Chapter 2, Site planning for additional details.
Outdoor splice enclosure
The outdoor splice enclosure houses all field splices for the FiberPatrol system. The splice
enclosure is also used to protect the FiberPatrol end module when it is installed outdoors. The
splice enclosure is mounted on the protected fence. For buried applications the splice enclosure is
protected inside a buried vault. There are 2 models of the splice enclosure available. The
GM0749-24 splice enclosure can house a maximum of 24 splices and the GM0749-48 can house
up to 48.
Figure 3 FiberPatrol connection module/fiber patch panel
1 RU splice enclosure
splice tray