Service loops
A 10 m (33 ft.) service loop is recommended for every 300 m (984 ft.) of fence-mounted sensor
cable. A 10 m service loop is also recommended on the hinged side of each gate that is protected
by sensor cable. In addition, a 10 m (33 ft.) splice point service loop is required for each section of
sensor cable at all splice locations. A 10 m service loop is typically comprised of 5 loops of cable
with a 60 cm (2 ft.) diameter. Service loops should be securely attached to the lower section of the
fence beside a fence post. Attach service loops directly to the fence fabric using one cable tie at
each 45º point of the loop (8 cable ties).
Figure 31 Sensitivity loop (heavy gauge post)
Figure 32 Sensitivity loop (corner post)
NOTE:
All double arrows indicate 30 cm (1 ft.) separation. All turns must respect the minimum bend radius.
NOTE:
All double arrows indicate 30 cm (1 ft.) separation.