SENS.413347.015RE
77
Cont. of table K.1
#
Function
Message format
6 Write query
address and
current loop
operation mode
6
Query data
Byte
Type
Value
Description
0
u-8
-
Query address (0 to 15)
1
enum
-
Current loop operation mode (0 - off, 1
- on)
Response data
Byte
Type
Value
Description
0
u-8
-
query address (0 to 15)
1
enum
-
current loop operation mode (0 - off, 1
- on)
Error codes
Cod
e
Description
1
Unknown error code
2
Incorrect selection
5
Incorrect number of bytes received
7
Write-protection enabled
12
Incorrect operation mode of current loop
16
Access restricted
7 Read query
address and
current loop
operation mode
Query data
no
Response data
Byte
Type
Value
Description
0
u-8
-
Query address (0 to 15)
1
enum
-
Current loop operation mode (0 - off,
1 - on)
Error codes
Code
Description
16
Access restricted
8 Read
classification of
dynamic
variables
Query data
no
Response data
Byte
Type
Value
Description
0
enum
-
Class. code Primary variable
1
enum
-
Class. code Secondary variable
2
enum
-
Class. code Third variable
3
enum
-
Class. code Fourth variable
Error codes
Code
Description
16
Access restricted
6
It is accepted to write only query address. Only one parameter should be transmitted for it.
Summary of Contents for SG-A1
Page 2: ...SENS 413347 015RE 2...
Page 98: ...SENS 413347 015RE 98 For notes...