Belonging to
Installation and user
guide
Important: Assembly / maintenance of the appliance must be carried out by qualified personnel and in
accordance with applicable laws and regulations.
The manufacturer assumes no responsibility for the use of products that have to comply with particular
environmental and / or installation standards.
Important note
Before connecting the equipment, it is recommended that you read the instruction manual carefully and keep
it for future reference. It is also recommended to perform the electrical connections correctly as per enclosed
drawings, observing the instructions and the Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side.
READ THE OPERATING INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT
The instrument: These operating instructions should be read by all persons using, maintaining or repairing
this product.
This product will satisfy the performances reported in these operating instructions, only in case of use,
maintenance or repair conforming with the directives by BEINAT S.R.L. as performed by personnel from
BEINAT S.R.L. or personnel duly authorized by BEINAT S.R.L.
Channel: Beinat gas solutions
Electric connections also available on
The new ATEX SG895 assembled probe is born from the elegance and prestige that has always distinguished BEINAT
S.r.l. and from the home fitness concept. The device has the capacity of controlling, through its Catalytic technology
sensors, the presence of:
Explosive Gases, TOXIC GAS
such as: Carbon Monoxide. (see table on page 5).
Thanks to its innovative technology advances, the probe is suitable to: industrial use and car parks.
The probe is managed by a microprocessor which not only supplies an alarm signal to the Control Unit
connected to it, but also executes a self-diagnosis and therefore an AUTOMATIC CALIBRATION in order
to obtain the maximum detection accuracy at all times.
The self-calibration means the probe adapts in harsh and variable temperature environments, avoiding false
alarms due to anomalous events.
The probe has a 4–20mA linear output, and can therefore be connected to one of the industrial control units
manufactured by BEINAT S.r.l.
Instrument of testing TS1008
To facilitate the reading of the functional parameters of the probe as well as the
control of annual operating, the BEINAT S.r.l. has built a new portable tester TS1008.
The tester allows to read all the data in the memory of the probes eand by serial
transmission, it prints the ticket that confirms the testing data, certifying your own work.
Ex d IIC T6 (85°C)
Ex tD A21 IP66 85° C
EUM1 10 ATEX 0169
Don't open when circuits alive
To wait for 60 seconds before the opening
Serial Number, see Declaration of Conformity attached
Atex Marcked
Safety Version Explosion Proof
BEINAT S.r.l.
CONFORMITY
EN 60079-0
EN 60079-1
EN 61241-0
EN 61241-1
EN 50270
0477 II2GD
Gas Detection Sensor SG895 ATEX
V. 0.0