SENS.413347.015RE
31
Value of parameter
nP
must be recorded in the table of configuration parameters of gas
detector configuration data sheet. Factory setting of
nP
parameter is 0 (disabled), unless
otherwise specified in purchase order.
8.4.2.14 Configuration of RS-485 port parameters
Viewing and configuration of RS-485 port parameters are only available for
"administrator" access level.
To set parameters it is required:
- enter configuration menu;
- run command
C231
(enter administrator mode);
- select
SADA
menu item;
- assign parameter
rS
(data rate) a required value:
1 - 2400 bit/s;
2 - 4800 bit/s;
3 - 9600 bit/s;
4 - 14400 bit/s;
5 - 19200 bit/s;
6 - 38400 bit/s;
- assign parameter
rP
(parity) a required value:
0 - no parity control;
1 - even;
2 - odd;
- assign parameter
SP
(protocol switch) a required value:
0 - automatic protocol detection;
1 - Modbus RTU protocol;
2 - SENS protocol;
- assign parameter
AA
(address) a required value;
- scroll to
End
item and exit with saving parameters;
- run command
C230
(exit administrator mode).
Factory parameters settings:
-
rS
- 5 (19200 bit/s);
-
rP
- 0 (no parity control);
-
SP
- 0 (automatic protocol detection);
-
AA
- 1.
Value of parameters rS,
rP
and
АА
must be recorded in the table of configuration
parameters of gas detector configuration data sheet.
8.4.2.15 Configuring of address, viewing of information parameters
Configuring of address, viewing of information parameters are performed in settings
menu item
Info
.
Menu item contains following subitems:
-
Еr
- gas detector error code;
-
Ad
- gas detector address in SENS system;
-
Pn
- program version (ID) of gas detector firmware.
For operation within SENS system, each device has an address.
Gas detector can be assigned address from 1 to 254. The address must be unique, i.e.
the devices connected to one line must not have the same addresses.
Gas detector sends a status byte to the line, only if its address is in range from 1 to 127.
Note - Certain switching units, power and switching units of SENS system support
handling of transducer status byte only if its address is in range from 1 to 31.