SENS.413347.015RE
91
Cont. of table K.1
#
Function
Message format
108
Write batch
mode
command
Error codes
Code
Description
1
Unknown error code
5
Incorrect number of bytes received
7
Write-protection enabled
16
Access restricted
109
Management
of batch
mode
Query data
Byte
Typ
e
Value
Description
0
u-8
-
Control code for batch mode (0 - off, 1
- on)
Response data
Byte
Typ
e
Value
Description
0
u-8
-
Control code for batch mode (0 - off, 1
- on)
Error codes
Code
Description
1
Unknown error code
5
Incorrect number of bytes received
7
Write-protection enabled
16
Access restricted
182
Calibration
Query data
Code
Type
Value
Description
0
u-8
-
Code of calibration command
1
enum
-
Irrelevant
2
enum
-
Measurement units code of
calibration variable
3-6
float
-
Variable value
Response data
Code
Type
Value
Description
0
u-8
-
Code of calibration command
1
enum
-
Code in query
2
enum
-
Measurement units code of
calibration variable
3-6
float
-
Variable value
Error codes
Code
Description
1
Unknown error code
5
Incorrect number of bytes received
7
Write-protection enabled