Figure 15 Schematic representation: connection of communications between MCU and battery module on SENEC.Home Li 2.5
9. Set the S <->M switch on the battery module to the M (Master) position.
This battery module is now the master for
further battery modules and controls the electronics and communication between further battery modules and the
MCU.
Figure 16 Battery module 1 assigned as the master
10. Now, depending on the configuration of your SENEC.Home Li storage unit, connect the further battery modules
with CAT 6 cables (figure 17 and associated table).
Configuration
Connection between
SENEC.Home Li 2.5
MCU -> UP module 1
SENEC.HomeLi 5.0
MCU -> UP module 1
LOW module 1 -> UP module 2
SENEC.HomeLi 7.5
MCU -> UP module 1
LOW module 1 -> UP module 2
LOW module 2 -> UP module 3
SENEC.HomeLi 10.0
MCU -> UP module 1
LOW module 1 -> UP module 2
LOW module 2 -> UP module 3
LOW module 3 -> UP module 4