36
5. Secure the modules (depending on the number for the SENEC.Home Li configuration) with the screws supplied to
the mounting rails at the positions illustrated in figure 14 (two screws with two washers for each module to the top
and bottom mounting rails).
6. Remove the rubber protective caps on the terminal connections.
7. Connect the terminals on the modules to the connection rails. Use the terminal connectors, terminal screws and
washers supplied for this. Eight terminal connectors are always provided to allow for the maximum number of bat-
tery modules possible. Connect the positive terminals first and then the negative terminals.
Risk of injury from electric shock!
The battery modules must always be switched off when being connected
to the DC connection (safety extra-low voltage <60 V).
Note!
Observe the tightening torque of 5 Nm.