21
12
15
Deutsche Energieversorgung GmbH
Wittenberger Straße 15
04129 Leipzig
Tel.: +49 341 87057-0
Mail: [email protected]
The electrical circuit of the SENEC.Home V2 Li was
labeled as _______________________ in the houses
distribution line and secured with a ____ A fuse.
Installation Company
Address
Date of installation
SENEC.IES is a brand name of Deutsche Energieversorgung GmbH.
Made in Germany Rev. 1.0
Follow the installation instruction!
Serial number:
Type: SENEC.Home V2 Li
2.5 / 5.0 / 7.5 / 10.0
U
AC
3 x 230 V
U
DC
46,8 V
I
3 x 16 A
C
5
at 30°
C
56,7 Ah (per module)
f
50 Hz
T
min
- T
max
0° C - 30° C
P
max
3 x 3680 W
S
max
3x 3680 VA
International
protection code
IP20
Year of
manufacture
2017
14
16
13
Figure 3 Product view of SENEC.Home Li (without cabling), rear view (on left) and left-hand side (on the right)
1
Display
9
Battery module
2
Buffer module CP-B 24/3.0
10
Positive terminal connection rail
3
24 V Power supply unit
11
Negative terminal connection rail
4
Installation contactor 24 - 40 V
12
Rear cable bushings
5
Grid and system protection device
13
DC isolating switch
6
SENEC.Inverter
14
Identification plate on side panel
7
MCU (Micro Control Unit) with NPU
15
Communication connections
8
Terminals for AC connection
16
Battery module (rear view)