SECURAM Systems Inc.
ScanLogic D22 Operation Guide Page 32
Step 5: Continue to hold the reset button in its depressed position for another 5 seconds; then
release.
A communication signal has now been sent to the Lock body telling it to convert from analog to digital
mode. The ScanLogic will now be able to operate the lock body.
Q: How do you know if the lock has been reset?
• The ScanLogic will not sound or beep when it resets. When a button is pressed, the
LCD will report “Link with Lock OK”. This indicates that the lock is now in digital mode
and has been successfully paired and the default codes will operate the lock. If the
LCD reports “Fail to Link with Lock”, repeat the reset process.
36.0 Testing
The ScanLogic D22 has 2 onboard system tests:
1) Cycle Testing
2) Hardware Testing
This is a very unique feature to SECURAM safe lock systems. As the access system on a fortified
steel box – the safe -- it is imperative that safe locks can provide solid performance. SECURAM
offers this unique menu selection that allows you to test the lock system performance through actual
Cycle Testing.
The “Hardware Testing” menu selection is not available for field use. It is however used in the
manufacturing process to check the board level components.
36.1 Cycle Testing
In order to perform a cycle test on the ScanLogic system, follow these steps:
Step1: Press the Menu/OK button.
Step 2: Using the “▲” or “▼” scroll to the System Menu and Press OK.
Step 3: Place the administrator’s finger on the scanner and/or enter an administrator’s code.. The
“Select Menu” message will be displayed.
Step 4: Scroll “▲” or “▼” to the menu selection “Cycle testing” and Press OK.