SECURAM Systems Inc.
ScanLogic D22 Operation Guide Page 28
34.0 Recover System (Level 1 & 2 & 3)
The ScanLogic Series safe lock systems have the ability to be reset to factory default settings using a
very unique secure method. Each system has a default recovery code. The Default code is
999999 - this code can be changed as necessary (refer to the Recovery Code Set selection).
Upon entry of the recovery code, the LCD screen displays an alpha-numeric code. This code
cannot be used to open the safe lock system or to change the code to factory default. The alpha
numeric code must be deciphered using SECURAM’s Authorization Code Generator Software.
The alpha-numeric code is entered into the software together with the encryption code. Through the
software, these codes are deciphered to generate a One Time Use Reset Code.
When entered into the ScanLogic safe lock, the lock and EntryPad are reset to factory default and the
system is recovered. Once used, the OTC (One Time Code) is no longer valid.
There is no limit to the number of times a system can be recovered using this process.
This is a vast improvement over other commonly used reset functions, as it offers a very secure
recovery method.
34.1 Recovery Code Set
The default Recovery Code for the ScanLogic Series is 999999. It is not necessary to change this
code, but if preferred this code can be changed with the following procedure.
Step 1: Press the “Menu/OK” button.
Step 2: Using the “▲” or “▼”, scroll to the “System Menu” and “Press OK”.