background image

SECURAM Systems Inc.

                                       

ScanLogic D22 Operation Guide                                              Page 1 

  

 

 

 

 

 

 

 

 

 

 

Document No.: FPC0601AD22 

Version No.:201222 

   

                       

 

 

 

 

 

       

ScanLogic D22 

Model: 

FPC-0601A-D22 

Biometric Safe Lock System

 

 

Operation Guide

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for FPC-0601A-D22

Page 1: ...SECURAM Systems Inc ScanLogic D22 Operation Guide Page 1 Document No FPC0601AD22 Version No 201222 ScanLogic D22 Model FPC 0601A D22 Biometric Safe Lock System Operation Guide...

Page 2: ...le User Section 9 0 Set Time Delay Section 9 1 Set Time Delay Override User Section 9 2 Duress Time Delay Section 9 3 Time Delay Unlock with an enrolled fingerprint or code Section 10 0 Set Number of...

Page 3: ...ble User Level 1 2 Section 24 0 Set Time Delay Level 1 2 Section 25 0 Unlock with an enrolled code Level 1 2 Section 26 0 Set Number of Locks Level 1 2 Section 26 1 Authorize access to Locks Level 1 2...

Page 4: ...ll be deleted when security level is changed The first code ID No 01 will be set to default 123456 Factory default security level is Level 3 Battery Replacement Instructions 1 On the back of EntryPad...

Page 5: ...r on the fingerprint scanner and hold Step 4 Hold your finger on the scanner until the above displays finish one by one Upon completion the first fingerprint with an ID No 01 is enrolled successfully...

Page 6: ...No 01 or 02 on the scanner and hold Step 4 After the fingerprint is verified successfully the LCD screen shows Select Menu press or to select Enroll New User Step 5 Follow the Steps 5 and 6 in Section...

Page 7: ...ode for example 512341 is the same as one of the enrolled codes 612345 LCD screen will show Code is similar and the code will not be accepted Enter a different code for this User 5 0 Enable User Code...

Page 8: ...ep 9 Enter a unique 6 digit code Step 10 Enter the same 6 digit code When the LCD screen displays ID 03 Code Saved the code of ID 03 has been set successfully Note If consecutive four digits of a new...

Page 9: ...r 02 on the scanner and hold Step 4 After the fingerprint is verified successfully press or to select Disable User Step 5 Press or to select the desired ID No to disable e g ID 03 Step 6 Press Menu OK...

Page 10: ...and or code to access the lock 9 0 Set Time Delay Security Level 3 Step1 Press Menu OK The screen will show Select Menu Step 2 Press or to select System Menu Press Menu OK again Step 3 Place an enroll...

Page 11: ...d the EntryPad can be programmed but the Lock Body cannot be unlocked After the original time delay has been changed successfully the new time delay settings will take place after the next unlocking s...

Page 12: ...Press or to select System Menu Press Menu OK again Step 3 Place an enrolled administrator s finger ID No 01 or 02 on the scanner and hold Step 4 After the fingerprint is verified successfully the LCD...

Page 13: ...When the EntryPad starts its Time Delay process user can operate the EntryPad normally but the Lock Body will not be unlocked even if the verification is successful If no valid code or enrolled finge...

Page 14: ...bered button that corresponds with the lock to be opened Then the lock will be unlocked automatically if verification is successful 10 1 Authorize access to locks Level 3 The ScanLogic D22 allows you...

Page 15: ...hether the group has authorization for each specified lock Letter o means the group has authorization to open this lock Letter x means the group does not have authorization For example To authorize us...

Page 16: ...fully the LCD screen shows Select Menu Press or to select Enable Sequence Press Menu OK If the number of Locks is more than one when unlocking in sequence is enabled Press 1 Lock 1 will be unlocked If...

Page 17: ...The following message will be displayed Step 5 Press Menu OK to confirm The system starts deleting users from ID No 01 to ID No 30 and then confirms the deletion as below Note1 After deleting all user...

Page 18: ...e entered within 60 seconds after the first code is successfully verified If all users are deleted Dual Mode will be disabled automatically 14 0 Penalty Time Wrong Code Entry Security Level 3 Penalty...

Page 19: ...Press Menu OK again Step 3 Place an enrolled administrator s finger ID No 01 or 02 on the scanner and hold Step 4 After the fingerprint is verified successfully press or to select Day Light Saving TM...

Page 20: ...nd Sunday of March and end at 2 00 on first Sunday of November Note Users can set Day Light Saving according to their certain condition 16 0 Maximum Door Open Time Security Level 3 Step 1 Press Menu O...

Page 21: ...ail Press Menu OK Step 5 The screen will show the last record of operation on the EntryPad Step 6 Press or to view more records 18 0 Set ID01 to Master Security Level 3 This programming command is use...

Page 22: ...he display will show the EntryPad Part Number 0601A D22 indicating this EntryPad is a ScanLogic D22 Capacity 30 Users Total Number of Users Used 00 User Total Number of Users enrolled in the system V9...

Page 23: ...e changed When security level is changed all fingerprints and codes will be deleted The first code ID01 will be set to default 123456 21 1 Enroll the first fingerprint and its bound code Security Leve...

Page 24: ...gain Step 3 Place the first enrolled finger on the scanner and hold You will be prompted to enter your Code After the fingerprint and its bound code are verified successfully press or to select Enroll...

Page 25: ...nistrator s code Step 4 After the fingerprint or code is verified successfully follow the steps in Section 5 0 and 6 0 to disable or enable a user 24 0 Set Time Delay Level 1 2 Step 1 Press Menu OK Th...

Page 26: ...em Menu Press Menu OK again Step 3 Place the administrator s finger on the scanner and or enter an administrator s code Step 3 After the fingerprint or code is verified successfully press or to select...

Page 27: ...K The screen will show Select Menu Step 2 Press or to select System Menu Press Menu OK again Step 3 Place the administrator s finger on the scanner and or enter an administrator s code Step 3 After th...

Page 28: ...are The alpha numeric code is entered into the software together with the encryption code Through the software these codes are deciphered to generate a One Time Use Reset Code When entered into the Sc...

Page 29: ...e The new Recovery Code has now been set DO NOT lose this code Without this code your system cannot be recovered 34 2 Recover System In the event that you need to recover the system during its use the...

Page 30: ...very feature if desired Step1 Press the Menu OK button Step 2 Using the or scroll to the System Menu and Press OK Step 3 Place the administrator s finger on the scanner and or enter an administrator s...

Page 31: ...de the following Simple Mechanical Reset procedure must be followed Step 1 Ensure that the EntryPad is not connected to the lock and that the battery is not connected to the EntryPad Step 2 Find the r...

Page 32: ...ic D22 has 2 onboard system tests 1 Cycle Testing 2 Hardware Testing This is a very unique feature to SECURAM safe lock systems As the access system on a fortified steel box the safe it is imperative...

Page 33: ...he manufacturing process to check the board level components Menus There are two menus on the ScanLogic D22 the root menu and a sub menu The sub menu is accessible by entering a valid code The menu se...

Page 34: ...Set ID01 to Master Delete All Users Enable Sequence Authorize Locks Set Number of Locks Recovery Code Set Recover System Encryption Key Set Renew Code Period Disable Recover Cycle Testing Duress Code...

Page 35: ...ery ScanLogic D22 can only be operated to lock or unlock Operations such as enrolling deleting or time delay setting are not permitted Specifications Fingerprint Sensor 500 DPI optical sensor Verifica...

Reviews: