8. Programming of articles / production
80 | 194
Reference Manual |Edition 5.0 (09-2016) |
CoaxCenter 6000
■
Color
■
Jacket diameter
■
Diameter of the individual layers (shield, dielectric, conductor).
See chapter
"8.3 Raw Material editor (Page 81)".
8.2.2
Processing editor
Opens the editor where the Processings are programmed. Here we define how the machine shall
process the raw material (blade setting, gap of feeding units etc.). See chapter
8.2.3
Wire length
Defines the total length, the raw material is to be cut to. The length entry is limited by the length of
the application type, thus the applications cannot be rendered useless through an insufficiently long
length entry.
8.2.4
Application type left / right
Defines the processing type for the left and right end. In a selection menu, the stripping type can be
defined.
8.2.5
Application editor left / right
Defines how the left and right end shall be processed. Touching the key, opens the application editor.
For more information, see chapter
8.2.6
Application editor window
Removes the jacket on a certain length (window) in the area of the left- and right ends. Also multiple
windows can be programmed.
8.2.7
Quantity of articles
Entering the quantity of articles to be produced in one run (per batch)
8.2.8
Produced articles
Shows the quantity of already produced articles since the last production start The value can be reset
to "0" with the command
[RESET PRODUCTION COUNTER]
.
8.2.9
Remaining articles
Shows the quantity of articles still to be produced since the last production start. The value can be set
back to the "Total" with the command
[RESET PRODUCTION COUNTER]
.
8.2.10
Reset production counter
Resets all production counters back to their initial state. This function is used when a new production
run is to be started. Produced articles, remaining articles and -batches are reset. Resetting the counter
values must be confirmed via a safety message.
Summary of Contents for CoaxCenter 6000
Page 4: ...Topic list 4 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 10: ...Table of contents 10 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 22: ...3 Transportation 22 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 48: ...5 Product description 48 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 78: ...7 General handling operation 78 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 110: ...10 User interface user levels 110 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 122: ...11 Diagnostics troubleshooting 122 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 154: ...15 Decommissioning disposal 154 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 155: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 155 194 APPENDIX...
Page 161: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 161 194...
Page 162: ...16 Appendix 162 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 16 2 PNEUMATIC SCHEMA...
Page 163: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 163 194...
Page 174: ...16 Appendix 174 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 186: ...16 Appendix 186 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 187: ...Personal notes Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 187 194...
Page 188: ...Personal notes 188 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 193: ......
Page 194: ......