2. Safety
Reference Manual |Edition 5.0 (09-2016) |
CoaxCenter 6000
17 | 194
2.4
GENERAL SAFETY NOTES
■
The product must only be operated when in good working order and condition. It must be
checked for intactness prior to the start of operation.
■
Never operate the product in an explosive or flammable environment.
■
Only operate the product in a dry, dust-free environment.
■
Processing carbon fiber or similar wire material disperses electrically conducting parts. This cause
short circuit in the electronics. Thus electronic components may be damaged. Use appropriate
suction appliances.
■
Before carrying out any maintenance or repair work, unplug the machine from the mains and/or
from the compressed air supply.
■
After completing maintenance work on the wiring or the electronic components, always perform
the safety check.
■
Only operate the product with connected earth conductor in the power cord.
■
Only use original
Schleuniger
equipment, especially interface connection cables (electromagnetic
compatibility).
■
Compulsory operate the product connected to the
Schleuniger
emergency stop circuit, if it is
operated together with peripheral devices in a production line. Only then can a safe interruption
of the complete production line be guaranteed during an emergency.
■
Only use supplied lubricating grease according to the instructions given in this manual.
■
Maintenance and modification work must be carried out by appropriate qualified personnel.
2.5
RESIDUAL RISKS
With the use of technical products are dangers associated. Dangers that could not be eliminated by
design measures and also not by protection devices are residual risks. The safety instructions in this
instructions refer to the known residual risks. Should be shown additional operational risks, the opera-
tor is obliged to inform
Schleuniger
immediately.
However, the following risks remain:
■
Danger due to catching body parts and clothing in the wire axis between peripheral devices and
the wire processing machine.
●
Always close off these areas
■
Danger due to stab wound or concussion injury or to death on the outlet. Wires/cables are ejec-
ted at high speed.
●
Always close off this area!
■
Danger due to blocked wire/cable on the inlet. Tensile forces can move to overturn machine,
peripheral or bobbin and injure the operator personnel.
●
Fixate machines and devices
●
Ensure a continuing wire/cable supply
■
Danger of tripping, falling, slipping due to connection cables, wire residue and air hoses lying
around.
●
Lay out connecting cables and hoses accordingly
●
Collect wire residue
●
Keep the area around free from non associated items.
■
Risk due to increased noise level while working in an environment with multiple machines.
●
Take up noise control measures!
■
Some wires/cables contain Talc. This contaminates the working environment during production.
●
Install the suction unit
Summary of Contents for CoaxCenter 6000
Page 4: ...Topic list 4 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 10: ...Table of contents 10 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 22: ...3 Transportation 22 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 48: ...5 Product description 48 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 78: ...7 General handling operation 78 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 110: ...10 User interface user levels 110 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 122: ...11 Diagnostics troubleshooting 122 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 154: ...15 Decommissioning disposal 154 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 155: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 155 194 APPENDIX...
Page 161: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 161 194...
Page 162: ...16 Appendix 162 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 16 2 PNEUMATIC SCHEMA...
Page 163: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 163 194...
Page 174: ...16 Appendix 174 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 186: ...16 Appendix 186 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 187: ...Personal notes Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 187 194...
Page 188: ...Personal notes 188 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 193: ......
Page 194: ......