11. Diagnostics / troubleshooting
Reference Manual |Edition 5.0 (09-2016) |
CoaxCenter 6000
111 | 194
DIAGNOSTICS / TROUBLESHOOTING
Errors and others can occur if excessive pollution affects the components. If the fan filters are dirty, it
is recognized specially with height ambient temperature.
Regular inspection and maintenance reduces the risk of unexpected faults and increases the reliabili-
ty and life cycle of the machine. Maintenance work must be accomplished according to the instruc-
tions and the time intervals listed. See chapter
"13.2 Maintenance schedule (Page 128)".
11.1
GENERAL FAULT LOCALIZATION
11.1.1
Safety instructions
General
Safety appliances must not be deactivated or removed inadvertently.
If a fault condition occurs always check first if the line power is switched on and then perform a diag-
nostic check.
Personnel qualification
The instructions in this chapter must be carried out by
qualified personnel
!
11.1.2
Behavior in case of an error
In case of an unrecoverable fault contact your local
Schleuniger
distributor, see
"Page 2"
.
Thereby, always report the software version number. Additionally inform about the selected raw
material type, stripping type and if the material was stripped in normal- or "Short mode".
If an error shows up on the touch screen which tends to be unrecoverable, the user has the option via
the button displayed, to save an error log to an USB memory stick inserted on the operator panel. This
log can then be handed over to the local
Schleuniger
distributor for analysis.
11.2
CAUSES OF FAULTS AND ACTION REQUIRED
Diagnostics
Cause of fault
Actions to be taken
The
CoaxCenter 6000
can
not be switched on.
■
Power supply faulty
■
Mains fuse(s) defective
■
Emergency stop button
engaged
■
Check the power supply
■
Check and/or replace the
mains fuses
■
Disengage the emergency
stop button
Production cannot be star-
ted
■
Entering of values not comple-
ted
■
Peripheral devices not switch-
ed on
■
Emergency stop button
engaged
■
Safety cover is open
■
Touch
[OK]
,
[LEAVE]
or
[CAN-
CEL]
■
Switch on peripheral devices
or brake connection to the
machine
■
Disengage the emergency
stop button
■
Close the safety cover
Summary of Contents for CoaxCenter 6000
Page 4: ...Topic list 4 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 10: ...Table of contents 10 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 22: ...3 Transportation 22 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 48: ...5 Product description 48 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 78: ...7 General handling operation 78 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 110: ...10 User interface user levels 110 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 122: ...11 Diagnostics troubleshooting 122 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 154: ...15 Decommissioning disposal 154 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 155: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 155 194 APPENDIX...
Page 161: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 161 194...
Page 162: ...16 Appendix 162 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 16 2 PNEUMATIC SCHEMA...
Page 163: ...16 Appendix Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 163 194...
Page 174: ...16 Appendix 174 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 186: ...16 Appendix 186 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 187: ...Personal notes Reference Manual Edition 5 0 09 2016 CoaxCenter 6000 187 194...
Page 188: ...Personal notes 188 194 Reference Manual Edition 5 0 09 2016 CoaxCenter 6000...
Page 193: ......
Page 194: ......