223
0
:
disabled
The driver is in normal read and write status. Whether the setting value of function codes can be modified is relevant to
the setting of user password and present operation status.
1
:
restore to factory defaults (all user parameters except motor parameters)
All user parameters except motor parameters will be restored to factory defaults.
2
:
restore to factory defaults (all user parameters)
All user parameters will be restored to factory defaults.
3
:
clear fault record
Clear the contents of fault record D-48
~
D-57. After this operation, this function code will clear to 0 automatically.
FE.14
write-protect
0
~
2
0
0
:
allow all parameters to be modified
(
some are not during operation
)
1
:
only allow F0.12, F0.13 and FE.14 to be modified
2
:
only allow PE.14 to be modified
FE.15
Parameter copy function
0
~
3
0
0
:
disabled
1
:
parameters upload to operation panel
If it is set at 1 and confirmed, the driver will display CP-1, and upload all function code parameters from control panel to
EEPROM in operation panel for storage.
2
:
all function code parameters download to the driver
If it is set at 2 and confirmed, the driver will display CP-2, and download all function code parameters from operation
panel except factory parameter to memory in main control panel, and refresh EEPROM.
3
:
download all function code parameters except motor parameters to the driver
If it is set at 3 and confirmed, the keypad will display CP-3, and the driver will download all function code parameters