39
F 0.08
Auxiliary
frequency
source
B
0
:
digital set 1 (keypad
▲
/
▼
key,
F0.12)
1
:
digital set 2 (terminal
UP/DOWN F0.13)
2
:
digital set 3 (communication
set)
3
:
AI1 analog set (0
~
10V/20mA)
4
:
AI2 analog set (0
~
10V)
5
:
pulse set (0
~
50KHZ)
6
:
easy PLC set
7
:
multistage speed run set
8
:
PID control set
9
:
panel potentiometer
1
3
○
F 0.09
Frequency source
0
:
main frequency source
A
1
:A
+K*
B
2
:A
-K*
B
3
:︱A
-K*
B︱
4
:
MAX
(A,
K*
B)
5
:
MIN
(A,
K*
B)
6
:
switch from
A
to K*B (A
prior to K*B)
7
:
switch form
A
to
(
A+K*B
)
(A prior to A+K*B)
8
:
switch form
A
to
(
A-K*B
)
(A prior to A-K*B)
Note 1
:
frequency switch needs
Note
2
:
compared
with
1
0
○