59
F6.35
DO output upper limit
0.00
~
50.00KHz
0.01KHz
50.00
○
F6.36
AI Multi-Point curve
selection
LED one’s place: AI1 Multi-Point
curve selection
0: disable
1: enable
LED ten’s place: AI1 Multi-Point
curve selection
0: disabled
1: enabled
LED hundred’s place: reserved
LED thousand’s palce: reserved
1
00
×
F6.37
AI1
curve
input
minimum
0.00
~【
F6.39
】
0.01V
0.00
o
F6.38
AI1
curve minimum
input
corresponds
setting
-200.0%
~
200.0%
note
:
range is relevant to F6.00
0.1%
0.0%
o
F6.39
AI1
Curve
turning
point1 input
【
F6.37
】~【
F6.41
】
0.01V
3.00
o
F6.40
AI1
Curve
turning
point1
input
corresponds setting
-200.0%
~
200.0%
note
:
range is relevant to F6.00
0.1%
30.0%
o
F6.41
AI1
Curve
turning
point2 input
【
F6.39
】~【
F6.43
】
0.01V
6.00
o
F6.42
AI1
Curve
turning
point2
input
corresponds setting
-200.0%
~
200.0%
note
:
range is relevant to F6.00
0.1%
60.0%
o
F6.43
AI1
curve
input
maxmum
【
F6.41
】~
10.00
0.01V
10.00
o