74
F8.32
PID Upper limit cutoff
frequency
【
F8.33
】~
300.00Hz
0.01Hz
50.00
×
F8.33
PID Lower limit cutoff
frequency
-300.00Hz
~【
F8.32
】
Note: When the frequency is
lower than -99.99Hz, set F0.18
one's place to 1
0.01Hz
0.00
×
F8.34
Sleeping frequency
0.00Hz
~
upper limit frequency
0.01Hz
0.00
×
F9 Group – MS and PLC Running, Traverse and Fixed Length Control
F9.00
PLC running mode
0
:
stop after single cycle
1
:
retain value after single cycle
2: continuous cycle of limited
times
3
:
continuous cycle
1
0
×
F9.01
Input mode of PLC
running
0
:
auto
1
:
manually input via defined
multi-function terminal
1
0
×
F9.02
PLC
running
state
saving after poweroff
0
:
not save
1
:
save the stage and frequency
when poweroff
1
0
×
F9.03
PLC restart mode
0
:
restart from the first stage
1
:
start from the stage where
the driver stops (fault)
2
:
start from the stage where
the driver stops(fault) at the
1
0
×