121
F4 Speed Loop, Torque and Flux Control Parameter
F4.00
Speed loop (ASR1) ratio gain
0.000
~
6.000
1.000
F4.01
Speed loop (ASR1) integral time
0.000
~
32.000s
1.000
F4.02
ASR1 filter time constant
0.000
~
0.100s
0.000
F4.03
Switch low point frequency
0.00Hz
~【
F4.07
】
5.00
F4.04
Speed loop (ASR2) proportional gain
0
~
6.000
1.500
F4.05
Speed loop (ASR2) integral time
0.00
~
32.000s
0.500
F4.06
ASR2 filer time constant
0.000
~
0.100s
0.000
F4.07
Switch high point frequency
【
F4.03
】~【
F0.16
】
upper limit freq.
10.00
Function codes F4.00~F4.07 are valid in no PG vector control mode.
In vector control mode, change speed response character by setting proportional gain P and integral time I of speed
regulator.
1
.
Speed regulator
(
ASR
)
has structure as showed in figure F4-1. KP is proportional gain P, TI is integral time I
。