237
Forward jog
Send frame
:
01H 06H 2000H 0002H 03CBH
Return frame
:
01H 06H 2000H 0002H 03CBH
Reverse jog
Send frame
:
01H 06H 2000H 000AH 020DH
Return frame
:
01H 06H 2000H 000AH 020DH
Set F8.00 parameter at 1
Send frame
:
01H 06H 0800H 0001H 4A6AH
Return frame
:
01H 06H 0800H 0001H 4A6AH
MODBUS reference frequency 40HZ
Send frame
:
01H 06H 2001H 0FA0H D642H
Return frame
:
01H 06H 2001H 0FA0H D642H
MODBUS PID reference 5V
Send frame
:
01H 06H 2003H 01F4H 721DH
Return frame
:
01H 06H 2003H 01F4H 721DH
MODBUS PID feedback 4V
Send frame
:
01H 06H 2004H 0190H C237H
Return frame
:
01H 06H 2004H 0190H C237H
MODBUS torque set at 80%
Send frame
:
01H 06H 2002H 0320H 22E2H
Return frame
:
01H 06H 2002H 0320H 22E2H
User password check
(
address AD00H and
1C00H interchangeable
)
Send frame
:
01H 06H AD00H 0001H 68A6H
Return frame
:
01H 06H AD00H 0001H 68A6H
Send frame
:
01H 06H 1C00H 0001H 4F9AH
Return frame
:
01H 06H 1C00H 0001H 4F9AH