Chapter 6: Volume Configuration
6-5
The alias of Stor_1 is changed to Disk2JBOD5 for easier identification and it is
noted to save the disk for snapshots.
storage set –s Stor_1 –na Disk2JBOD5 –info save_for_snap
shots
The V-Switch supports write cache enabling for increased performance. Use
the CLI command
storage disk set
to enable or disable the write cache.
storage disk set
You need to define two parameters to change a device’s write cache setting:
S
WITCH
P
ARAMETER
D
EFINITION
S
TATUS
E
XAMPLE
-d
DISK
DISK DEVICE
MANDATORY
Disk2JBOD5
-wce
WRITE CACHE
ENABLED
WRITE CACHE
FUNCTION
MANDATORY
YES OR NO
yes
The V-Switch also recognizes all write-protected storage devices. Use the CLI
command
storage details
to view a device’s details, including if it is write-
protected.
storage details
You need to define one parameter to view a disk’s details:
S
WITCH
P
ARAMETER
D
EFINITION
S
TATUS
E
XAMPLE
-s
STORAGE
ALIAS OF STORAGE
TO VIEW
MANDATORY
Disk2JBOD5
Table
6-2: Storage
Details
Alias: Disk2JBOD5
Entity Name:
2000002037a9551e
LUN(Logical Unit Number)
0000000000000000
Vendor Name:
SEAGATE
Additional Info:
Transport type:
Fiber Channel
Oper. Status:
Enabled
Time since last Update:
8 days 3h:12m:16 sec 37
(1/60 Sec)
SCSI Version:
3
Summary of Contents for I3.1.1205
Page 1: ......
Page 6: ...SPCLI3 1 1205 SANRAD V Switch CLI User Manual ...
Page 22: ...xvi SANRAD V Switch CLI User Manual ...
Page 40: ...2 12 SANRAD V Switch CLI User Manual ...
Page 80: ...4 28 SANRAD V Switch CLI User Manual ...
Page 118: ...6 26 SANRAD V Switch CLI User Manual ...
Page 152: ...7 34 SANRAD V Switch CLI User Manual ...
Page 186: ...9 8 SANRAD V Switch CLI User Manual ...
Page 214: ...10 28 SANRAD V Switch CLI User Manual ...