9-4
SANRAD V-Switch CLI User Manual
Example:
The top-level volume Stripe 1 is removed along with its component volumes,
Simple 2, 4, 8 & 10.
volume remove -all –vol Stripe1
Disk 3
Disk 4
Simple 2
Disk 1
Simple 1
Simple 4
Simple 3
Disk 2
Simple 8
Disk 5
Simple 7
Simple 10
Disk 6
Simple 9
Disk 7
Disk 8
100
93
Simple 5
Simple 6
Simple 11
Simple 12
JBOD 1
JBOD 2
Striped
Volume 1
Figure
9-2. Stripe 1 Volume and Supporting Hierarchy Removed
Replacing a Volume
If you are working in
a V-Switch cluster,
the volume must be
replaced on both V-
Switches.
You can replace a volume with another volume. Use the CLI command
volume replace
after a disk failure to replace a volume used in a
storage hierarchy with a volume on a functional disk. This is only a
‘physical’ replacement. The data on the failed disk is not copied to the
new volume.
If you are replacing a volume used as part of a mirrored volume, continue
with the CLI command volume mirror synch to synchronize the
replacement volume with the other mirrored volume(s). See
“Synchronizing a Volume”.
Summary of Contents for I3.1.1205
Page 1: ......
Page 6: ...SPCLI3 1 1205 SANRAD V Switch CLI User Manual ...
Page 22: ...xvi SANRAD V Switch CLI User Manual ...
Page 40: ...2 12 SANRAD V Switch CLI User Manual ...
Page 80: ...4 28 SANRAD V Switch CLI User Manual ...
Page 118: ...6 26 SANRAD V Switch CLI User Manual ...
Page 152: ...7 34 SANRAD V Switch CLI User Manual ...
Page 186: ...9 8 SANRAD V Switch CLI User Manual ...
Page 214: ...10 28 SANRAD V Switch CLI User Manual ...