11-18
SANRAD V-Switch CLI User Manual
cluster show
This command shows the keep alive parameters of a cluster.
cluster show
Table
11-12: Cluster Table
Last Keep Alive:
1
KeepAlive Int(s):
2
Susp Int(s):
6
Dead Int(s):
10
Failover: Enabled
State: Running
cluster set
This command allows you to modify a cluster’s parameters.
cluster set
S
WITCH
P
ARAMETER
D
EFINITION
S
TATUS
E
XAMPLE
-kai
KEEP ALIVE
INTERVAL
TIME BETWEEN
ALIVE SIGNALS
FROM NEIGHBORS
MANDATORY IF
CHANGING
5
-sint
SUSPICIOUS
INTERVAL
TIME FROM WHEN A
SIGNAL WAS
EXPECTED BUT NOT
RECEIVED
MANDATORY IF
CHANGING
10
-fint
FAILOVER INTERVAL
TIME WHEN
SUSPICIOUS
INTERVAL IS
EXCEEDED
MANDATORY IF
CHANGING
20
Example:
The Keep Alive interval is set to 5 seconds. That is, every 5 seconds an alive
signal is sent out to all neighboring V Switches. The neighboring V Switches
register a suspicious interval after 10 seconds without an alive signal. This is
the equivalent of 2 missed keep alive intervals. After a total of 20 seconds, from
the first missed alive signal, the neighboring V Switches register a dead
interval. This is the equivalent of 4 missed keep alive intervals.
cluster set –kai 5 –sint 10 –dint 20
Summary of Contents for I3.1.1205
Page 1: ......
Page 6: ...SPCLI3 1 1205 SANRAD V Switch CLI User Manual ...
Page 22: ...xvi SANRAD V Switch CLI User Manual ...
Page 40: ...2 12 SANRAD V Switch CLI User Manual ...
Page 80: ...4 28 SANRAD V Switch CLI User Manual ...
Page 118: ...6 26 SANRAD V Switch CLI User Manual ...
Page 152: ...7 34 SANRAD V Switch CLI User Manual ...
Page 186: ...9 8 SANRAD V Switch CLI User Manual ...
Page 214: ...10 28 SANRAD V Switch CLI User Manual ...