Chapter 10: Routine V-Switch Maintenance
10-15
Disks and Subdisks
Discovering Storage Devices
The V-Switch default algorithm for storage devices discovery is using the SCSI
command REPORT LUNS. Certain storage devices either do not support this
command or do not respond according to the SCSI standard. To discover these
devices, the REPORT LUNs command must be disabled. If certain devices in
the SAN are not being discovered by the V-Switch, use the CLI command
device set
to disable or re-enable device discovery via REPORT LUNs.
device set
You need to define one parameter to change the V-Switch storage device
discovery mode:
S
WITCH
P
ARAMETER
D
EFINITION
S
TATUS
E
XAMPLE
-rld
REPORT
LUN
DISCOVERY
MODE FOR
DISCOVERING
DEVICE
LUN
S
MANDATORY
YES OR NO
DEFAULT
:
YES
no
See “
device set
,” for the full list of switch parameters for the CLI command
device set
.