69
Unless stated otherwise, all dimensions are given in mm.
MANTO®
Step 1
Use the included bolts and nuts to attach the Panel Connection Unit (code:609080) to
the panel rib.
5.3.2 Removing PM Aligning Wedge Clamp from Aligning Wedge Clamp Holder and attaching to panel joint
The PM Aligning Wedge Clamp can be used to connect MANTO Panels side by side
(vertical joint).
Stacked MANTO G3 and G3/M panels (horizontal joints) can also be connected to one
another with the PM Aligning Wedge Clamp. The PM Aligning Wedge Clamp should be
attached such that it rests against a V-rib.
WARNING
Risk of injury from falling formwork elements!
If the PM Aligning Wedge Clamp on the horizontal rib is not attached over a V-rib, the
panel connection is not secure.
A PM Aligning Wedge Clamp on a horizontal rib always has to be attached over a V-rib!