Formwork restraint
Unless stated otherwise, all dimensions are given in mm.
Re-using Anchor Bolts
When re-using Anchor Bolts check the bolt beforehand with the Checking Gauge
(code:443501).
Checking Gauge (code:443501).
Anchor Bolt MM+SSK 16 x 130 mm
(code:443500).
If a hole is drilled incorrectly, a new hole must be drilled at a distance equal to at least
twice the actual depth of the incorrectly drilled hole.
Anchor Bolts can be re-used, but the same hole cannot be used a second time.
14.1.3 Tying panels to the ground with the Panel Anchor Bracket
The Panel Anchor Bracket (code:605999) can be attached to MANTO panels as shown
below to secure MANTO panels against uplift.
MANTO panel
Panel Anchor Bracket
(code:605999).
Note the correct orientation.
Anchor Bolt MM+SSK 16 x 130 mm
(code:443500)
WARNING
Risk of injury from overturning formwork elements!
The Customer is responsible for verifying that the concrete strength of the existing
structure is in accordance with the specifications shown in section 4.