![SAFWAY Huennebeck MANTO G3 User Manual Download Page 208](http://html1.mh-extra.com/html/safway/huennebeck-manto-g3/huennebeck-manto-g3_user-manual_3403797208.webp)
208
Storage and transport
Unless stated otherwise, all dimensions are given in mm.
20.1.3 Single panels
Single MANTO panels can be turned over the long way with 2no. MANTO Loading
Adapters (does not apply to MANTO panels G3). The Loading Adapters are connected
at the corners of the panel by engaging the connecting pin in the hole (Ø 24 mm) in the
panel.
MANTO Loading
Adapter
Ø 24 hole
Turning of the panels is only permitted as shown here. Lifting multiple connected
MANTO panels with the MANTO Loading Adapter is not permitted.
The separate operating instructions of the MANTO Loading Adapter have to be fol-
lowed.
20.1.4 Assembled panels
MANTO Crane Adapter
MANTO formwork with an area of up to 30.00 m
2
can be transported with a pair of
MANTO Crane Adapters.
MANTO Crane Adapter
(code:446710)
140
≤ 60°
MANTO Crane
Adapter over the
joint, gripping both
panels.
WARNING
Risk of injury from falling formwork elements!
The internal angle of the slings on the crane hook should not exceed 60°.
Otherwise the slings and crane hook will be overloaded.