59
Unless stated otherwise, all dimensions are given in mm.
MANTO®
4.5 Rules for using MANTO panels of different generations
It is essential to follow these rules when using MANTO panels of different generations
in the same formwork:
• All panels must be able to withstand the same fresh concrete pressure. Pay particular
attention to the reduced concrete pressure permitted for MANTO Panels G1 (refer to
• Panels of different generations can be connected horizontally (side-by-side) (Refer to
section 4.6 on page 60). The rules for connecting panels horizontally apply to all
generations of panels.
• Single-sided operated ties can only be used in MANTO panels G3 or G3 M.
• Panels of different generations can be used opposite one another as shown in the
following tables.
MANTO panels
Two-sided tying
Advancing side
Closing side
G2
G3
G3 M
G2
✓
✓
–
G3
✓
✓
–
G3 M
–
–
✓
MANTO panels
Single-sided tying
Advancing side
Closing side
G2
G3
G3 M
G2
–
–
–
G3
–
✓
–
G3 M
–
–
✓
MANTO Giant Panels*
Two-sided tying
Advancing side
Closing side
G2
G3
G3 M
G2
✓
–
–
G3
–
✓
–
G3 M
–
–
✓
MANTO Giant Panels*
Single-sided tying
Advancing side
Closing side
G2
G3
G3 M
G2
–
–
–
G3
–
✓
–
G3 M
–
–
✓
*Also applies to MANTO G3 M Panels 240/330 and MANTO G3 M Panels 240/270
All other rules contained in this user guide apply to MANTO panels G1, G2, G3 and
G3 M.
Summary of Contents for Huennebeck MANTO G3
Page 1: ...MANTO Large frame panel formwork User guide...
Page 9: ...9 Unless stated otherwise all dimensions are given in mm MANTO...
Page 61: ...61 Unless stated otherwise all dimensions are given in mm MANTO MANTO G3 M MANTO G3 M...
Page 219: ...219 Unless stated otherwise all dimensions are given in mm MANTO...