80
Height extensions up to 500 mm on site
Unless stated otherwise, all dimensions are given in mm.
7.3 Extensions up to 400 mm (with MANTO Aligning Panel Clamp)
Step 1
Use 2no. MANTO Aligning Panel Clamps (
B,
code:448000) to attach a timber beam (
A
)
to the top edge profile of the panel to be extended.
Step 2
Nail a second timber beam (
C
) to the upper arms of the MANTO Aligning Panel Clamps.
There are nail holes at the ends of the arms of the MANTO Aligning Panel Clamp to
accommodate the nails.
Step 3
Nail plywood (
D
), 21 mm thick and max. 400 mm high, to the timber beams.
B
max. 400
A
D
50–75
280
C
7.4 Extensions up to 500 mm (with Multipurpose Waler 100)
Step 1
Fasten the Multipurpose Waler 100 (
A
, code:450764) to the uppermost H-rib on the
MANTO panels with the aid of Waler Spanners (
B
, code:452053) and Tension Nuts (
C
,
code:197332) or with PLATINUM 100 Multi Bolts (
D
, code:605810) and MANTO Tie Nuts
(
E
, code:464600).
Step 2
Nail 2no. timber beams (
F
) to the Multipurpose Waler 100. The Multipurpose Waler 100
has nail holes in the flanges.
Step 3
Nail plywood (
G
), 21 mm thick and max. 500 mm high, to the timber beams.
max. 500
B&C/D&E
F
G
max. 375
max.
200
A
Summary of Contents for Huennebeck MANTO G3
Page 1: ...MANTO Large frame panel formwork User guide...
Page 9: ...9 Unless stated otherwise all dimensions are given in mm MANTO...
Page 61: ...61 Unless stated otherwise all dimensions are given in mm MANTO MANTO G3 M MANTO G3 M...
Page 219: ...219 Unless stated otherwise all dimensions are given in mm MANTO...