79
Unless stated otherwise, all dimensions are given in mm.
MANTO®
7 Height extensions up to 500 mm on site
Should it be required, it is possible to create extensions in height of up to 500 mm on
top of the MANTO Panels without the need for extra panels.
Should these extensions not provide enough extra height, it is also possible to join
MANTO panels on top of each other to further increase the height of the formwork
(height extension) (Refer to page 81).
Extending panels vertically will increase the tie loads. Keep this in mind when planning
the design.
Check that all connectors are tight and, if necessary, retighten before every use and
every time they are moved.
7.1 Extensions up to 100 mm (with Panel Clamp)
Step 1
Use Panel Clamps to attach timber beams to the top edge profile of the panel to be
extended.
Step 2
Nail plywood, 21 mm thick and max. 100 mm high, to the timbers.
Timber beam
21 mm plywood
Panel Clamp
(code:448010)
max.
100
50–75
120
7.2 Extensions up to 300 mm (with Panel Clamp and MANTO Add-on Piece)
Step 1
Use Panel Clamps to attach MANTO Add-on Pieces to the top edge profile of the panel
to be extended. Maximum between the MANTO Add-on Pieces: 750 mm.
Step 2
Nail plywood, 21 mm thick and max. 300 mm high, to the MANTO Add-on Pieces. The
MANTO Add-on Pieces have a wooden strip for this purpose.
Add-on Piece (code:450157) +
Panel Clamp (code:448010)
max.
750
21 mm plywood
max.
300
Summary of Contents for Huennebeck MANTO G3
Page 1: ...MANTO Large frame panel formwork User guide...
Page 9: ...9 Unless stated otherwise all dimensions are given in mm MANTO...
Page 61: ...61 Unless stated otherwise all dimensions are given in mm MANTO MANTO G3 M MANTO G3 M...
Page 219: ...219 Unless stated otherwise all dimensions are given in mm MANTO...