8
MAINTENANCE
8-10
8.1.2.8
Check operation of the safety microswitch SQ42 in the turn-plate spacer
- Turn on the machine with the main switch.
- Press key
RESET
to reset the machine.
- Open the cover of the microswitch and make sure power supply is not uninterrupted in normally closed contacts
with an electric multitester.
- Release the fork of the microswitch by raising the cover of the turn-plate spacer and make sure power supply is
uninterrupted in normally closed contacts with an electric multitester.
8.2
SPECIAL MAINTENANCE OPERATIONS
Special training is required to perform special maintenance work which may therefore be carried only by the
manufacturer’s expert personnel. For this reason, these operations are not dealt with in this manual.