062AZ005A
7
ADJUSTMENTS
7-4
7.2.2
PRESSURE ADJUSTMENT
- Release the knob
7
by pulling it out.
- Turn adjustment knob
7
until gauge
9
reads the desired pressure setting.
- When the adjustment has been made, push the knob fully in to lock it in place.
7.2.3
PRESSURE SWITCH SETTING
- Release the knob
8
by pulling it out.
- Turn the knob to direction “
-
.“
- Use the pressure adjuster
7
to set the operating pressure for which the pressure switch comes into action. This
value can be read on the gauge
9
.
- Under these conditions, the LED
12
stays on and the LED
11
goes off.
- Turn knob to direction “
+
” until the LED
12
goes out and the LED
11
comes on.
- Push the pressure switch knob fully in to lock it in place.
- Reset pressure adjuster
7
to the operating value.
- Make sure there are no air leaks in the pneumatic circuit by pressing the test key in the air control unit.
- The values recommended for pressure are 3.5 bar (minimum) and 6.0 bar (maximum).