062AZ005A
MAINTENANCE
8
8-3
Unit and intervention point
(3)
Action taken
Every X hours
Lubricant
Time (min) (2)
When deemed
necessary
.
180
360
720
(1 month)
1440
(2 months)
2160
(3 months)
4320
(6 months)
8640
(1 year)
12960
(18 months)
25920
(3 years)
(4)
Type
(1)
Q.ty
ELECTRICAL
SYSTEM
Electrical cabinets
Drain any condensate and other liquids
•
5
8.1.2.5
Cleaning and maintenance
•
60
Electrical boxes and cabinets
Check seals
•
30
Electrical cabinet fans
Clean filters
•
20
Electrical
cabinet conditioners
Make sure the condensate drain hose is not clogged
•
5
Maintenance (consult specific documentation)
Photocells
Check operation
•
1
Photocells
Clean
•
1
SP
ARK TESTER
device
brush
8.1.2.6
Check operation
•
5
SAFETY
DEVICES &
GUARDS
Emergency stop buttons
Check operation
•
5
Cover safety microswitch
8.1.2.7
Check operation
•
5
Audible/visual indicators
Verify they work efficiently
•
5
Grounding system
Check connections and integrity of cables
•
15
Electrical cables
Check connections and integrity of cables
•
15
Dif
ferential safety devices for
switches
Verify they work efficiently
•
30
(1) Refer to the
ADHESIVES
AND LUBRICANTS DA
TA
SHEET
supplied under separate cover
.
(2) Estimated machine downtime required to perform the operation.
(3) Refer to the paragraphs that deal with the operation.
(4) Contact SACMI customer service before attempting to perform operations for additional information.
(5)
The actual duration is strictly related to the work conditions.
º
Symbol indicating the time interval for the first maintenance job, if dif
ferent from the one indicated with symbol
•
.
Summary of Contents for Imola CHS Series
Page 2: ......
Page 4: ...062AZ005A...
Page 48: ...062AZ005A 2 FEATURES 2 32...
Page 76: ...062AZ005A 4 INSTALLATION 4 10...