MAINTENANCE
8-8
8.1.2.5
Cleaning/replacing the pneumatic system filter
- Take off the cover
13
.
- Take out the filter cartridge and clean or replace it, if necessary.
- Clean the filter slot and the part inside the cover.
- Insert the filter.
- Remount the cover
13
.
FIGURE 8.1.2.5 - CLEANING/REPLACING THE PNEUMATIC SYSTEM FILTER
1
Pneumatic control unit
2
Hose fitting for connection to mains
3
¼” fitting for connecting an air blow gun (if provided)
4
Filter clogging indicator: if it comes out of the control unit body, the filter is clogged.
The clogging indicator stays in the control unit body when the air supply is shut off.
5
Air supply valve
6
Button for operating the control unit solenoid valve in manual mode.
The solenoid valve opens whenever the electricity supply goes off.
7
Pressure control knob
8
Pressure switch adjustment knob
9
Pressure gauge
10
Control unit solenoid valve led: on, if supplied
11
Not used
12
Pressure switch led: on, if the pressure detected is higher than that set on the pressure switch
13
Filter cover
14
Fitting, Condensate drain line
E0004
WARNING!
The cover should be tightened to a torque not greater than 6 Nm in order not to damage it.
5
1
2
3
4
6
10
8
9
7
11
12
13
14