T6897
062AZ005A
7
ADJUSTMENTS
7-10
7.3.5
ADJUSTING THE BLOWERS FOR THE SOLENOID VALVE AND SENSORS ON THE CONVEYOR
BELT
- Loosen the fixing screws
1
and bring the reject nozzle
2
to 5 mm from the cap to be rejected (dimension
recommended and referred to the cap centered on the belt).
- Tighten the fixing screws.
- Loosen the reject nozzle
2
and bring it to 10 mm from the cap slide belt (recommended dimension).
FIGURE 7.3.5 -
ADJUSTING THE BLOWERS FOR THE SOLENOID VALVE AND SENSORS ON THE
CONVEYOR BELT
1
Fixing screws
2
Reject nozzle
1
2
5
10