INSTALLATION
4
4-9
4.3.2.2
Ground connection
Connect the points marked with symbol
E0006
(417-IEC-5019) directly to an efficient ground system.
Only specially trained personnel are authorized to make the connections in the areas specified on the relative
nameplates.
Before tightening the clamp screws provided, remove any paint from the press body at the points where the ground
conductors are connected. This will improve electrical continuity.
E0004
WARNING!
Failure to ground the indicated parts may cause serious machine damage and personal injury.
Unless otherwise specified, the connections are to be made by the installation worker appointed by the customer.
E0004
WARNING!
Failure to ground the indicated parts may cause serious machine damage and personal injury.
Unless otherwise specified, the connections are to be made by the installation worker appointed by the customer.
The power and ground cables should have an adequate cross-section and be constructed so that they are
suitable for the specific wiring system. Information about the correct size is given on the installation drawings
provided at the time of machine purchase.