T6907
062AZ005A
8
MAINTENANCE
8-6
8.1.2.4
Replacing the belt
- Loosen the dowels
17
and remove the encoder
6
.
- Loosen the screws
1
and remove the cover
2
.
- Loosen the nuts
3
and loosen the screws
4
to easily remove the belt
5
.
- Loosen the screw
7
.
- Loosen the screws
8
and remove the plate
9
.
FIGURE 8.1.2.4/A - REPLACING THE BELT
- Loosen screws
10
and remove guards
11
and
13
.
- Loosen screws
12
and remove guard
14
.
- Detach the air hose of the coupling
15
.
- Unplug the connector
16
of the solenoid valve.
- Replace the conveyor belt
5
.
- To put back all the parts perform the above operations in reverse order taking care to tension and center the
conveyor belt again as indicated in the CONVEYOR BELT TENSIONING paragraph in this chapter.