T5712
T6910
A
A
062AZ005A
MAINTENANCE
8
8-9
8.1.2.6
Cleaning the electrical cabinet and electrical cabinet fans
- Clean the components inside the electrical cabinets with a suction device (do not use compressed air jets).
- Check and tighten the terminal blocks, bolts and connectors, if necessary.
FIGURE 8.1.2.6 - CLEANING THE ELECTRICAL CABINET AND ELECTRICAL CABINET FANS
8.1.2.7
Checking operation of the SPARK TESTER device brush
Set an electric multitester to uninterrupted power supply testing and touch the uncovered part of the orange cable
with one tip and the star wheel with the other.
If the multitester beeps, this means that the brush still operates correctly. If the multitester makes no sound, replace
the brush.
FIGURE 8.1.2.7 - CHECKING OPERATION OF THE SPARK TESTER DEVICE BRUSH
1
Brush
1