002AZ001A
7 - 11
ADJUSTMENTS
7
ADJUSTING SENSITIVITY
The sensitivity for quality checking can be adjusted by setting the “low threshold, defective caps” and the “high threshold,
defective caps” parameters on the “CCM” page of the control display. This allows the dimension field within which the
product is considered acceptable to be defined. The system is able to detect 0.25 mm thickness variations of the “central
panel” of the product. Refer to the Instructions B manual for further information on how to set this data.
Figure 7.3.2/B - SENSITIVITY ADJUSTMENT
T1898
X
X-(> 0,25 )
X+(> 0,25)