002AZ001A
7 - 14
7
ADJUSTMENTS
7.6
COOLING SYSTEM
E0004P
ATTENTION!
Do not modify the values used for the thermostatic valve and temperatures set for the upper and lower tools,
indicated on the Data sheet, under any circumstances.
The thermostatic valve changes the oil temperature in the hydraulic system. This valve is adjusted manually.
The temperature of the tools are set on the EXTRUDER PAGE of the microprocessor control system.
The temperature set for the upper and lower tools affect the quality, characteristics and dimensions of the caps. See
the Data sheet for further information.
7.7
INSTALLING AND REMOVING THE TOOLING
The tooling to be used is strictly related to the type of product handled. The specifications for this unit are given in the
spare parts catalogue for the tools.
E0004P
WARNING!
The actuators move up slowly due to the low pressure at which the hydraulic fluid flows but exert the required force
for formation once they reach the end of their stroke.
Always make sure no one has their hands and/or limbs between the tools and that no objects are accidentally
between them.