002AZ001A
7 - 10
7
ADJUSTMENTS
T1596
7.3.2
ADJUSTING THE QUALITY CONTROL UNIT
MECHANICAL ADJUSTMENTS
For proper operation, each reference surface must be 3 +/- 0.05 mm away from the sensor while the actuators carrying
out the pressing cycle.
Proceed as follows:
- turn the mode key selector to set-up
- open the safety guards
- start the hydraulic power unit with the related button
- activate the high pressure valve with the related button
- wait until the actuators start the pressing cycle
- loosen the ring nuts (1)
- place a thickness gauge between the sensor (2) and the reference surface (3)
- adjust the height of the reference surface (3)
- tighten the ring nuts (1)
- close the safety guards and turn the mode key selector to MAN
- start the hydraulic power unit with the related button
- activate the low pressure valve with the related button
- turn the forming drum until all the actuators have moved down
- stop rotation
E0004P
WARNING!
The actuators move up slowly due to the low pressure at which the hydraulic fluid flows but exert the required force
for formation once they reach the end of their stroke.
Always make sure no one has their hands between the tools and that no objects are accidentally between them.
Figure 7.3.2/A - MECHANICAL ADJUSTMENT
A
Precharge
1
Ring nuts
2
Sensor
3
Reference surface
1
3
2
3
±
0,05
A
Summary of Contents for CCM001
Page 2: ...002AZ001A 0 2 TABLE OF CONTENTS...
Page 4: ...002AZ001A 0 4 TABLE OF CONTENTS...
Page 10: ...002AZ001A 0 10 TABLE OF CONTENTS...
Page 14: ...002AZ001A 1 4 1 GENERAL INFORMATION T2525 1 8 MACHINE IDENTIFICATION PLATE...
Page 50: ...002AZ001A 2 36 2 MACHINE FEATURES...
Page 106: ...002AZ001A 7 20 7 ADJUSTMENTS...
Page 119: ...002AZ001A 8 13 MAINTENANCE 8 T2575 Figure 8 1 2 2 50 kg h EXTRUDER 6 31 33 32 7 8 1 3 17 5...
Page 162: ...002AZ001A 8 56 8 MAINTENANCE...
Page 164: ...002AZ001A 9 2 9 DECOMMISSIONING...