002AZ001A
6 - 4
6
OPERATING INSTRUCTIONS
6.2
STARTING AND STOPPING THE MACHINE
SET-UP OPERATIONS
All the operations which the user has to access the machine directly, that is with the safety guards open are considered
part of set up.
Use maximum care when carrying out these operations. The mode selector (19-23) on the keyboard must be turned
to SET UP.
NOZZLE DRAIN
- Start the plasticization unit by using key 9.
- Press key 20 and keep it pressed until some molten material flows out. Collect and throw this material in the by-pass
collection box.
- Thoroughly clean the top of the nozzle.
ACTUATOR UPWARD MOVEMENT
Start the hydraulic power unit by using key 8.
Start the high pressure circuit by using key 10.
E0004P
WARNING!
The actuators move slowly up due to the low flow rate of the hydraulic fluid but exert the forming force once they
have reached the end of their stroke. It is therefore necessary to make sure nobody’s hands are between the tools
and that there are no objects have accidentally been left between them.
OPERATION IN MANUAL MODE
The mode selector (19-23) on the keyboard has to be turned to MAN.
The safety guards must be closed.
Under these conditions all the control keys are active except for key 20.
PREHEATING
The machine can automatically be preheated by setting the date and time the system is to come on.
Access the “Extruder programming” page and enter the data.
For further information on how to enter data, refer to the “Instructions B” manual.
Summary of Contents for CCM001
Page 2: ...002AZ001A 0 2 TABLE OF CONTENTS...
Page 4: ...002AZ001A 0 4 TABLE OF CONTENTS...
Page 10: ...002AZ001A 0 10 TABLE OF CONTENTS...
Page 14: ...002AZ001A 1 4 1 GENERAL INFORMATION T2525 1 8 MACHINE IDENTIFICATION PLATE...
Page 50: ...002AZ001A 2 36 2 MACHINE FEATURES...
Page 106: ...002AZ001A 7 20 7 ADJUSTMENTS...
Page 119: ...002AZ001A 8 13 MAINTENANCE 8 T2575 Figure 8 1 2 2 50 kg h EXTRUDER 6 31 33 32 7 8 1 3 17 5...
Page 162: ...002AZ001A 8 56 8 MAINTENANCE...
Page 164: ...002AZ001A 9 2 9 DECOMMISSIONING...